Calculations based on 55℃ according to EN16147
* 5 YEAR WARRANTY SUBJECT TO ANNUAL SERVICE AGREEMENT *
KERS WEATHERBY SERIES | KERS WEATHERBY-W160 | KERS WEATHERBY-W230 | KERS WEATHERBY-W300 |
---|---|---|---|
Tank Volume (Litres) | 160 | 230 | 300 |
Heating Capacity (W) | 2010 | 2010 | 2010 |
Max Power Input | 560w | 560w | 560w | COP (EN255/3) | 4,5 | 4,5 | 4,5 |
COP (EN16147) | 3,5 | 3,5 | 3,5 |
Electrical Connection | 230v/50Hz/1Ph | 230v/50Hz/1Ph | 230v/50Hz/1Ph | AMP | 10 | 10 | 10 |
Working Pressure | 8 BAR | 8 BAR | 8 BAR |
Max Water Temp (No immersion) | 70℃ | 70℃ | 70℃ | Refrigerant | R134A | R134A | R134A |
Electrical Heater Optional (W) | 3000 | 3000 | 3000 |
Duct Minimum Diameter (mm) | 150mm/220mm x 90mm | 150mm/220mm x 90mm | 150mm/220mm x 90mm | Max Pressure (Pa) | see fan spec | see fan spec | see fan spec |
Flow rate minimum (I/s) | 80 | 80 | 80 |
Corrosion Protection | Vacuum enameled | Vacuum enameled | Vacuum enameled |
Weight (Kg) | 105 | 120 | 130 | Dimensions (mm) HxD | 1494 x 668 | 1638 x 668 | 1888 x 668 |